Enclosed Medical Protections:
OCP Over Current Protection
OVP Over Voltage Protection
OTP Over Temperature Protection
SCP Short Circuit Protection 
   

PowerAC InputDC InputDC OutputsSpecial FeaturesApprovalsModel
IEC60601-1 3rd Ed.2xMOPP
30W85~265V120~370V5, 12, 15, 24V (Adjust. ±20%), 48V (Adjust.-20/+10%)OCP, OVP, ADJ. Output Voltagex HWS30ME
40W85~264V 5, 7.5, 9, 12, 15, 18, 24, 28, 36, 48, 53V (Adjust. ±10%)Operating Altitude 5000 meter, OCP, OVP, SCP, ADJ. Output VoltagexxMED40US
40W85~264V 5/3.3, 12/5, 12/3.3, 15/5, 24/5, 28/5, 5/3.3/-5, 5/3.3/12, 5/3.3/-12, 12/5/-5, 12/5/-12, 12/3.3/5, 12/3.3/-12, 15/5/-15, 24/5/12VOperating Altitude 5000 meter, Dual/Triple Output, OCP, OVP, SCP xxMED40UD/T
50W85~265V120~370V5, 12, 15, 24V (Adjust. ±20%), 48V (Adjust.-20/+10%)OCP, OVP, ADJ. Output VoltagexHWS50ME
65W85~265V 5/3.3, 12/5, 12/3.3, 15/5, 24/5, 28/5, 5/3.3/-5, 5/3.3/12, 5/3.3/-12, 12/5/-5, 12/5/-12, 12/3.3/5, 12/3.3/-12, 15/5/-15, 24/5/12VOperating Altitude 5000 meter, Dual/Triple Output, OCP, OVP, SCP xxMED65UD/T
65W85~265V 5, 7.5, 9, 12, 15, 18, 24, 28, 36, 48, 53V (Adjust. ±10%)Operating Altitude 5000 meter, OCP, OVP, SCP, ADJ. Output VoltagexxMED65US
85-120W90~264V12, 24, 48V (Adjust. ±4%)OCP, OVP, OTP, EMI Class I (with PE) & Class II (without PE), with 10CFM FanxxMQF120E
100W85~265V120~370V5, 12, 15, 24V (Adjust. ±20%), 48V (Adjust.-20/+10%)OCP, OVP, ADJ. Output VoltagexxHWS100ME
100W85~265V 12, 15, 18, 24, 28, 36, 48V (Adjust. ±10%)OCP, OVP, ADJ. Output VoltagexxMED100
150W85~265V120~370V5, 12, 15, 24V (Adjust. ±20%), 48V (Adjust.-20/+10%)OCP, OVP, ADJ. Output VoltagexHWS150ME
150W85~265V 12, 15, 24, 28, 36, 48V (Adjust. ±10%)Operating Altitude 5000 meter, OCP, OVP, SCP, ADJ. Output VoltagexxMEF150
240W90~264V12, 15, 24, 48V (Adjust. ±4%)OCP, OVP, OTP, EMI Class I (with PE) & Class II (without PE), with 10CFM FanxxMQF240E
300W85~265V120~370V5, 12, 15, 24V (Adjust. ±20%), 48V (Adjust.-20/+10%)OCP, OVP, ADJ. Output Voltage, Remote on/off, parallel mode xHWS300ME
450W90~264V 12, 15, 24, 28, 36, 48, 53V (Adjust. ±10%)Operating Altitude 5000 meter, OCP, OVP, SCP, ADJ. Output VoltagexxMEH450
500W90~264V127~370V12, 15, 24, 48V (Adjust. ±4%)OCP, OVP, ADJ. Output Voltage, Remote on/off, 5V Standbye, with Fanx MQF500E
600W85~265V120~370V5, 12, 15, 24V (Adjust. ±20%), 48V (Adjust.-20/+10%)OCP, OVP, ADJ. Output Voltage, Remote on/off, parallel mode xHWS600ME
1000W85~265V120~370V5, 12, 15, 24, 36V (Adjust. ±20%), 48V (Adjust.-20/+10%)OCP, OVP, ADJ. Output Voltage, Remote on/off, parallel mode xHWS1000ME
1000W90~264V24, 28, 32, 34, 36, 42, 48VOCP, OVP, 5VDC Standby Output, Fan Power, Remote SensexPM1100
1500W85~265V120~370V5, 12, 15, 24, 36V (Adjust. ±20%), 48V (Adjust.-20/+10%)OCP, OVP, ADJ. Output Voltage, Remote on/off, parallel mode, Volt. prog.xHWS1500ME