Bricks

Rated Power (W)
DC Input (VDC)
No. of Outputs
Load Regulation
DC Outputs (VDC)
I/O Isolation Voltage
Approval 1
Approval 2
Approval 3
Eff. (%)
Oper. Temp. Range (°C)
Special Features
Package
Dimensions (Inch)
Model
33 ~ 50 9~18, 18~36, 36~75 1 Yes 3.3, 5, 12, 15, 24 1.5kVDC IEC/UL/EN60950-1 89 -40 ~ +100 2:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB50
33 ~ 50 9~36, 18~75 1 Yes 3.3, 5, 12, 15, 24, 48 1.5kVDC IEC/UL/EN60950-1 87 -40 ~ +100 4:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB50W
50 ~ 75 9~18, 18~36, 36~75 1 Yes 3.3, 5, 12, 15, 24 1.5kVDC IEC/UL/EN60950-1 89 -40 ~ +100 2:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB75
50 ~ 75 9~36, 18~75 1 Yes 3.3, 5, 12, 15, 24, 48 1.5kVDC IEC/UL/EN60950-1 85 -40 ~ +100 4:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB75W
50 ~ 300 200~425 1 Yes 2.97~3.96, 4~6, 9.6~13.2, 12.5~16.5, 19.2~26.4, 23.3~30.8, 38.4~52.8 3kVAC IEC/UL/CSA/EN60950-1 IEC/UL/CSA/EN62368-1 EN62477-1 OVC III 92 -40 ~ +85 Up to 425 Vdc Input, Cover HVDC Telecom Requirements, no External Transformer Needed Quarter Brick/Half Brick 1.46 x 0.5 x 2.3 / 2.4 x 0.5 x 2.28 PH-A280
66 ~ 100 9~18, 18~36, 36~75 1 Yes 3.3, 5, 12, 15, 24 1.5kVDC UL60950-1 89 -40 ~ +100 2:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB100
66 ~ 100 9~36, 18~75 1 Yes 3.3, 5, 12, 15, 24, 28, 48 1.5kVDC UL60950-1 89 -40 ~ +100 4:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB100W
75 18~36, 36~75 2 (isolated) Yes 5/3.3 , 5/2.5 1.5kVDC UL60950-1 84 -40 ~ +100 2:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB75-Dual
85 9~40 1 Yes 5, 12, 15, 24, 28 2.25kVDC UL/EN60950-1 CSA60950-1 MIL-STD-883F and MIL-STD-202G 91 -40 ~ +115 Rugged Package with Encapsulation, up to 115°C Baseplate Temperatures, designed for 28V DC Networks Quarter Brick 2.39 x 2.20 x 0.50 HQA85
99 ~ 150 36~75 1 Yes 3.3, 5, 12, 15, 24 1.5kVDC UL60950-1 89 -40 ~ +100 2:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB150
99 ~ 150 9~36, 18~75 1 Yes 3.3, 5, 12, 15, 24, 28, 48 1.5kVDC UL60950-1 91 -40 ~ +100 4:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB150W
100 9~36, 18~75 1 Yes 3.3, 5, 12, 15, 24, 48 1.5kVDC IEC/UL/EN60950-1 93 -40 ~ +105 4:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHE100W
100 9~36, 18~75 1 Yes 3.3, 5, 12, 15, 24 1.5kVDC UL60950-1 88 -40 ~ +100 4:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Quarter Brick 2.28 x 1.45 x 0.50 CQB100W
100 9~18, 18~36, 36~75 1 Yes 3.3, 5, 12, 15, 24, 28, 48 2.25kVDC IEC/UL/EN60950-1 UL:E193009 93 -40 ~ +105 2:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 HAE100
150 9~75 1 Yes 5, 12, 15, 24, 28, 48 1.5kVDC UL60950-1 90 -40 ~ +100 Wide Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB150W8
150 180~425 1 Yes 5, 12, 24, 28, 48 3kVAC UL60950-1 90 -40 ~ +100 Wide Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Quarter Brick 2.28 x 1.45 x 0.50 CQB150-300S
150 8.5~22, 16.5~36, 33~75 1 Yes 3.3, 5, 12, 15, 24, 30, 48 2.25kVDC IEC/UL/EN60950-1 IEC/EN/UL62368-1 UL:E193009 92 -40 ~ +105 2:1 Input, OCP, OTP, OVP, UVP, SCP, adjust. Output, Remote On/Off Quarter Brick 2.28 x 1.45 x 0.50 QAE150
165 ~ 200 18~36, 36~75 1 Yes 3.3, 5, 12, 24, 48 1.5kVDC UL60950-1 93 -40 ~ +100 2:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB200
165 ~ 200 10~36, 18~75 1 Yes 3.3, 5, 12, 15, 24, 48 1.5kVDC UL60950-1 89 -40 ~ +100 4:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB200W
180 ~ 400 200~400 1 Yes 1.8, 3.3, 5.0 3kVAC EN60950-1 UL1950 CSA950 85 -40 ~ +85 Wide Input, OCP, OTP, OVP , adjust. Output, Up to 100A Output Current Full Brick 4.60 x 2.40 x 0.50 PAF400F
200 8.5~22, 16.5~36, 33~75 1 Yes 3.3, 5, 12, 15, 24, 28, 48, 53 2.25kVDC IEC/UL/EN60950-1 UL:E193009 93 -40 ~ +115 2:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 HAE200
231 ~ 350 18~36, 36~75 1 Yes 3.3, 5, 12, 15, 24, 48 1.5kVDC UL60950-1 92 -40 ~ +100 2:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB350
264 ~ 500 18~36, 36~76 1 Yes 3.3, 5.0, 12, 28 1.5kVDC UL/CSA/EN60950-1 90 -40 ~ +100 2:1 Input, OCP, OTP, OVP , adjust. Output, Remote On/Off, parallel Opt. Full Brick 4.60 x 2.40 x 0.50 PAF500F
300 180~425 1 Yes 5, 12, 24, 28, 48 3kVAC IEC/UL60950-1 90 -40 ~ +100 Wide Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB300-300S
300 9~36, 18~75 1 Yes 5, 12, 15, 24, 28, 48 1.5kVDC UL60950-1 92 -40 ~ +100 4:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Half Brick 2.28 x 2.40 x 0.50 CHB300W
400 9~36, 18~75 1 Yes 5, 12, 15, 24, 28, 48 1.5kVDC UL60950-1 90 -40 ~ +100 4:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Full Brick 4.60 x 2.40 x 0.50 CFB400W
450 200~400 1 Yes 12, 24, 28, 48 3kVAC UL/CSA/EN60950-1 91 -40 ~ +100 Wide Input, OCP, OTP, OVP , adjust. Output, Remote On/Off, parallel Opt. Full Brick 4.60 x 2.40 x 0.50 PAF450F280
600 ~ 700 18~36, 36~75 1 Yes 12, 24, 28, 32, 48 1.5kVDC UL60950-1 92 -40 ~ +100 4:1 Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Full Brick 4.60 x 2.40 x 0.50 CFB600
600 180~425 1 Yes 12, 24, 48 3kVAC UL60950-1 91 -40 ~ +100 Wide Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Full Brick 4.60 x 2.40 x 0.50 CFB600-300S
600 19~36, 36~76 1 Yes 12, 28 1.5kVDC UL/CSA/EN60950-1 90 -40 ~ +100 2:1 Input, OCP, OTP, OVP , adjust. Output, Remote On/Off, parallel Opt. Full Brick 4.60 x 2.40 x 0.50 PAF600F
600 200~400 1 Yes 12, 24, 28, 48 3kVAC UL/CSA/EN60950-1 91 -40 ~ +100 Wide Input, OCP, OTP, OVP , adjust. Output, Remote On/Off, parallel Opt. Full Brick 4.60 x 2.40 x 0.50 PAF600F280
700 36~76 1 Yes 12, 28 1.5kVDC UL/CSA/EN60950-1 91 -40 ~ +100 2:1 Input, OCP, OTP, OVP , adjust. Output, Remote On/Off, parallel Opt. Full Brick 4.60 x 2.40 x 0.50 PAF700F
750 200~425 1 Yes 12, 15, 24, 28, 36, 48 3kVAC UL60950-1 90 -40 ~ +85 Wide Input, OCP, OTP, OVP, SCP, UVL, Remote On/Off, adjust. Output Full Brick 4.60 x 2.40 x 0.50 CFB750-300S